Independent verification.

Measurable performance.

Design compliance.

Your System Meets Specification. But Does It Perform?

For Facilities Managers and Consultants, system performance needs to be proven, not assumed.

Common issues such as:

-Inconsistent temperatures

-Poor BMS control

-High energy consumption

are rarely caused by equipment failure.

In most cases, they come down to incomplete or inaccurate hydronic balancing and flow rate commissioning.

If flow rates have not been properly measured and set, the system is not operating to design intent.

Independent Hydronic Balancing Specialists

At Helios Gas, we provide independent hydronic balancing and flow rate commissioning for commercial heating and chilled water systems.

We use Comdronic hydronic manometer instrumentation to measure actual system performance and ensure every circuit is achieving the correct flow rate in line with design specifications and CIBSE guidance.

We work independently of installation contractors, giving you clear, objective validation of system performance.

Our Commissioning Method

We fix the flow, not replace the system

1

System Verification

  • Review of system layout and design intent

  • Identification of commissioning sets, DRVs and binder points

  • Confirmation of access for accurate measurement

2

Flow Rate Commissioning and Hydronic Balancing

We connect into the system via binder points using DRVs and commissioning sets.

Using a hydronic manometer, we:

  • Measure live flow rates across circuits

  • Set terminal units to design duty

  • Balance the system to achieve correct distribution

3

Reporting and Diagnostics

Our reports are built around measured data, not assumptions. We provide:

  • Verified flow rates against design requirements

  • Evidence of blocked strainers and filters

  • Identification of pump performance issues

  • Indications of incorrect pipe sizing or distribution problems

The Difference You’ll Feel

Hydronic balancing delivers:

  • Systems operating to design intent

  • Balanced flow across all circuits

  • Reduced energy consumption

  • Improved BMS control and stability

  • Lower plant stress and maintenance costs

  • Consistent internal conditions

    You also have documented proof of performance.

Unbalanced Systems Cost You Daily

If a system is not properly commissioned, inefficiency becomes part of normal operation.

Hydronic balancing and flow rate commissioning correct this without the need for system replacement.

Book a Commissioning Assessment

Make sure your system is operating as designed and backed by measured data.

Typical Projects

Office buildings

Healthcare Facilities

Schools and Universities

Industrial and Process Environments

The Helios Difference

We don’t replace systems that can be fixed. We make them work properly.

  • Commercial hydronic specialists

  • Proven measurement methods using hydronic manometers

  • CIBSE-aligned approach

  • Clear, reportable outcomes

Bring Your System Back to Design Performance

Stop fighting your heating.

Start fixing it.